/v2/hypervisor/projects/{project_id}/dynamips/vms ------------------------------------------------------------------------------------------------------------------------------------------ .. contents:: POST /v2/hypervisor/projects/**{project_id}**/dynamips/vms ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Create a new Dynamips VM instance Parameters ********** - **project_id**: UUID for the project Response status codes ********************** - **400**: Invalid request - **201**: Instance created - **409**: Conflict Input ******* .. raw:: html
Name Mandatory Type Description
auto_delete_disks boolean automatically delete nvram and disk files
aux integer auxiliary console TCP port
chassis string router chassis model
clock_divisor integer clock divisor
console integer console TCP port
disk0 integer disk0 size in MB
disk1 integer disk1 size in MB
dynamips_id integer ID to use with Dynamips
exec_area integer exec area value
idlemax integer idlemax value
idlepc string Idle-PC value
idlesleep integer idlesleep value
image string path to the IOS image
image_md5sum ['string', 'null'] checksum of the IOS image
iomem integer I/O memory percentage
mac_addr string base MAC address
midplane enum Possible values: std, vxr
mmap boolean MMAP feature
name string Dynamips VM instance name
npe enum Possible values: npe-100, npe-150, npe-175, npe-200, npe-225, npe-300, npe-400, npe-g2
nvram integer amount of NVRAM in KB
platform string platform
power_supplies array Power supplies status
private_config string path to the IOS private configuration file
private_config_base64 string private configuration base64 encoded
private_config_content string Content of IOS private configuration file
ram integer amount of RAM in MB
sensors array Temperature sensors
slot0 Network module slot 0
slot1 Network module slot 1
slot2 Network module slot 2
slot3 Network module slot 3
slot4 Network module slot 4
slot5 Network module slot 5
slot6 Network module slot 6
sparsemem boolean sparse memory feature
startup_config string path to the IOS startup configuration file
startup_config_base64 string startup configuration base64 encoded
startup_config_content string Content of IOS startup configuration file
system_id string system ID
vm_id Dynamips VM instance identifier
wic0 Network module WIC slot 0
wic1 Network module WIC slot 0
wic2 Network module WIC slot 0
Output ******* .. raw:: html
Name Mandatory Type Description
auto_delete_disks boolean automatically delete nvram and disk files
aux ['integer', 'null'] auxiliary console TCP port
chassis string router chassis model
clock_divisor integer clock divisor
console integer console TCP port
disk0 integer disk0 size in MB
disk1 integer disk1 size in MB
dynamips_id integer ID to use with Dynamips
exec_area integer exec area value
idlemax integer idlemax value
idlepc string Idle-PC value
idlesleep integer idlesleep value
image string path to the IOS image
image_md5sum ['string', 'null'] checksum of the IOS image
iomem integer I/O memory percentage
mac_addr string base MAC address
midplane enum Possible values: std, vxr
mmap boolean MMAP feature
name string Dynamips VM instance name
npe enum Possible values: npe-100, npe-150, npe-175, npe-200, npe-225, npe-300, npe-400, npe-g2
nvram integer amount of NVRAM in KB
platform string platform
power_supplies array Power supplies status
private_config string path to the IOS private configuration file
private_config_base64 string private configuration base64 encoded
project_id string Project UUID
ram integer amount of RAM in MB
sensors array Temperature sensors
slot0 Network module slot 0
slot1 Network module slot 1
slot2 Network module slot 2
slot3 Network module slot 3
slot4 Network module slot 4
slot5 Network module slot 5
slot6 Network module slot 6
sparsemem boolean sparse memory feature
startup_config string path to the IOS startup configuration file
startup_config_base64 string startup configuration base64 encoded
system_id string system ID
vm_directory string
vm_id string Dynamips router instance UUID
wic0 Network module WIC slot 0
wic1 Network module WIC slot 0
wic2 Network module WIC slot 0