/v2/compute/projects/{project_id}/dynamips/nodes ------------------------------------------------------------------------------------------------------------------------------------------ .. contents:: POST /v2/compute/projects/**{project_id}**/dynamips/nodes ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Create a new Dynamips VM instance Parameters ********** - **project_id**: Project UUID Response status codes ********************** - **201**: Instance created - **400**: Invalid request - **409**: Conflict Input ******* .. raw:: html
Name Mandatory Type Description
auto_delete_disks boolean Automatically delete nvram and disk files
aux ['null', 'integer'] Auxiliary console TCP port
chassis string Cisco router chassis model
clock_divisor integer Clock divisor
console ['integer', 'null'] Console TCP port
console_type enum Possible values: telnet, none
disk0 integer Disk0 size in MB
disk1 integer Disk1 size in MB
dynamips_id ['integer', 'null'] Dynamips ID
exec_area integer Exec area value
idlemax integer Idlemax value
idlepc string Idle-PC value
idlesleep integer Idlesleep value
image string Path to the IOS image
image_md5sum ['string', 'null'] Checksum of the IOS image
iomem integer I/O memory percentage
mac_addr ['null', 'string'] Base MAC address
midplane enum Possible values: std, vxr
mmap boolean MMAP feature
name string Dynamips VM instance name
node_id Node UUID
npe enum Possible values: npe-100, npe-150, npe-175, npe-200, npe-225, npe-300, npe-400, npe-g2
nvram integer Amount of NVRAM in KB
platform string Cisco router platform
power_supplies array Power supplies status
private_config_content string Content of IOS private configuration file
ram integer Amount of RAM in MB
sensors array Temperature sensors
slot0 Network module slot 0
slot1 Network module slot 1
slot2 Network module slot 2
slot3 Network module slot 3
slot4 Network module slot 4
slot5 Network module slot 5
slot6 Network module slot 6
sparsemem boolean Sparse memory feature
startup_config_content string Content of IOS startup configuration file
system_id string System ID
usage string How to use the Dynamips VM
wic0 Network module WIC slot 0
wic1 Network module WIC slot 0
wic2 Network module WIC slot 0
Output ******* .. raw:: html
Name Mandatory Type Description
auto_delete_disks boolean Automatically delete nvram and disk files
aux ['integer', 'null'] Auxiliary console TCP port
chassis string Cisco router chassis model
clock_divisor integer Clock divisor
console ['integer', 'null'] Console TCP port
console_type enum Possible values: telnet, none
disk0 integer Disk0 size in MB
disk1 integer Disk1 size in MB
dynamips_id integer ID to use with Dynamips
exec_area integer Exec area value
idlemax integer Idlemax value
idlepc string Idle-PC value
idlesleep integer Idlesleep value
image string Path to the IOS image
image_md5sum ['string', 'null'] Checksum of the IOS image
iomem integer I/O memory percentage
mac_addr ['null', 'string'] Base MAC address
midplane enum Possible values: std, vxr
mmap boolean MMAP feature
name string Dynamips VM instance name
node_directory string Path to the vm working directory
node_id string Node UUID
npe enum Possible values: npe-100, npe-150, npe-175, npe-200, npe-225, npe-300, npe-400, npe-g2
nvram integer Amount of NVRAM in KB
platform string Cisco router platform
power_supplies array Power supplies status
project_id string Project UUID
ram integer Amount of RAM in MB
sensors array Temperature sensors
slot0 Network module slot 0
slot1 Network module slot 1
slot2 Network module slot 2
slot3 Network module slot 3
slot4 Network module slot 4
slot5 Network module slot 5
slot6 Network module slot 6
sparsemem boolean Sparse memory feature
status enum Possible values: started, stopped, suspended
system_id string System ID
usage string How to use the Dynamips VM
wic0 Network module WIC slot 0
wic1 Network module WIC slot 0
wic2 Network module WIC slot 0